Home > Products > Electrical Training Equipment >
High‑Performance Detection and Sensor Conversion Technology Experiment Box Comprehensive Sensor Signal Conversion Training Teaching Experiment Kit

High‑Performance Detection and Sensor Conversion Technology Experiment Box Comprehensive Sensor Signal Conversion Training Teaching Experiment Kit

sensor conversion experiment box

signal conversion training kit

teaching sensor experiment equipment

Place of Origin:

HENAN,CHINA

Brand Name:

RUIMU

Certification:

ISO9001/ISO45001/ISO14001

Model Number:

RM-F168

Chat Now
Request A Quote
Product Details
Product Name:
Electrical Training Equipment Models,Fuse Training System,Digital Product Maintenance Examination Educational Equipment,Mechanical Training Equipment,Teaching Equipment
Material:
China Origin
Function:
Training,wide Use For The Training And Teaching,Electric Teaching Training,educational Training Equipment,educational Training Electrical Equipments/tools For Driving Learning
Application:
Physical Electrics Experiment,Training Center,educational Training Equipment
Type:
Electrical And Electronic Basis Examination&training Equipment Series
Size:
650×400×230mm
Item Name:
Electrical Teaching Equipment Model,Teaching Instrument
Usage:
Education School Sensor Experiment
Training Bench:
Lab Equipment For School
Category:
Power Training Equipment,Electrical Engineering Trainer
Package:
Wooden Box
Weight:
285kgs
Highlight:

sensor conversion experiment box

,

signal conversion training kit

,

teaching sensor experiment equipment

Payment & Shipping Terms
Minimum Order Quantity
1 unit
Price
/
Packaging Details
Wooden packaging
Delivery Time
30-45 work days
Payment Terms
T/T
Supply Ability
/
RELATED PRODUCTS
Contact Us
Product Description

Product Introduction

The RM-F168 Detection and Sensor Conversion Technology Experiment Box is our company's latest product, developed for sensor and teaching experiments, and suitable for different categories and levels of professional teaching experiments. It can complete teaching experiments for courses such as "Sensor Principles and Applications," "Automatic Detection Technology," "Industrial Automation Instrumentation and Control," "Non-electrical Quantity Measurement Technology," and "Sensor and Measurement Control Technology." It provides ideal laboratory equipment for universities, vocational schools, and technical colleges to quickly establish or expand their laboratories and offer experimental courses.

Technical Specifications

  1. Input Power: AC220V±5% 50±1Hz
  2. Rated Current: ≤5A
  3. DC Power Supply: ±5V ±15V
  4. Voltage Regulation Factor: ±1%
  5. Voltage Ripple: ≤10mV
  6. Nonlinearity Error: ≤5%
  7. Measurement Accuracy: ≤1%
  8. Power Consumption: 100VA
  9. Output Current: 1A
  10. Relative Temperature: -5℃~40℃
  11. Relative Humidity: <85% (25℃)
  12. Experimental Chamber Dimensions: 650*400*230mm

Experimental chamber technical requirements:

  1. The experimental box provides four sets of DC regulated power supplies: ±5V and ±15V, with short-circuit protection, and one heating source.
  2. Low-frequency signal generator: 1Hz-30Hz continuously adjustable output, Vp-p value 10V, maximum output current 0.5A.
  3. Audio signal generator: 0.4KHz-10KHz continuously adjustable output, output voltage range: 0VP~10VP continuously adjustable, maximum output current: 0.5A (RMS 0.4KHz).
  4. Differential amplifier: Passband 0-10KHz, can be configured as in-phase, inverting, or differential, DC amplifier with gain 1-150 times.
  5. Digital voltmeter: Three-and-a-half-digit display, range ±2V, ±20V, input impedance 100KΩ, accuracy 1%.
  6. Digital frequency/tachometer: Composed of four digital tubes and two LEDs, input impedance 100KΩ, accuracy 1%. Frequency measurement range: 1-9999 Hz; Rotational speed measurement range: 1-9999 r/min.
  7. Mechanical pressure gauge: 0-40 kPa, accuracy 2%.
  8. Manual pneumatic pressure source: 0-40 kPa.

Oscillator requirements:

  1. Low-frequency oscillator: Continuously adjustable output from 1Hz to 30Hz, Vp-p value 10V, maximum output current 0.5A.
  2. Vibration source: Vibration frequency 1Hz-30Hz, resonant frequency approximately 12Hz.
  3. Rotation source: Driven by 0-12V DC power supply, adjustable speed range 0~2400 rpm.

The sensor experiment is as follows:

* indicates a thinking experiment

  1. Single-Arm Bridge Performance Experiment of Resistive Sensors
  2. Half-Bridge Performance Experiment of Resistive Sensors
  3. Full-Bridge Performance Experiment of Resistive Sensors
  4. Comparison Experiment of Single-Arm, Half-Bridge, and Full-Bridge Resistive Sensors
  5. Vibration Experiment of Resistive Sensors*
  6. Electronic Scale Experiment of Resistive Sensors*
  7. Characteristic Experiment of Variable Area Capacitive Sensors
  8. Characteristic Experiment of Differential Capacitive Sensors
  9. Vibration Experiment of Capacitive Sensors*
  10. Electronic Scale Experiment of Capacitive Sensors*
  11. Characteristic Experiment of Differential Transformers
  12. Characteristic Experiment of Self-Inductive Differential Transformers
  13. Performance Experiment of Differential Transformers
  14. Influence of Excitation Frequency on the Characteristics of Differential Transformers*
  15. Vibration Experiment of Differential Transformers*
  16. Electronic Scale Experiment of Differential Transformers*
  17. Rotation Speed Measurement Experiment of Photoelectric Sensors
  18. Rotation Direction Measurement Experiment of Photoelectric Sensors
  19. Proximity Hall Sensor Experiment
  20. Rotation Speed Measurement Experiment of Hall Sensors*

Send your inquiry directly to us

Privacy Policy China Good Quality Electrical Training Equipment Supplier. Copyright © 2026 Henan Ruimu Intelligent Technology Co., Ltd. . All Rights Reserved.